The AYSIX line of sensors for DO – ORP – PH – TSS
(DO) dissolved oxygen measurement technology
Dissolved oxygen sensors use an optical technique called fluorescence technology, which does not consume oxygen like all standard membrane sensors. The optical oxygen sensor does not require sensor caps, membranes, filling solutions or routine calibration and maintenance. Our continuous DO sensors come standard with ¼” O.D. tube connectors for integrated jet cleaning and 10 m (33ft) of sensor communication cable. Additional cable length is available on request.
Specifications
Measurement range: 0 to 25 ppm
Accuracy: 1% of reading or 0.05 ppm, whichever is greater.
Repeatability: 0.01 ppm
Response time: 95% in less than 60 seconds
Resolution: 0.01 ppm below 4.00, 0.1 ppm above 4.0
Drift: less than 1% per year
Temperature range: 0°C to 60°C
1-½” MNPT mounting thread
10 m (33ft) sensor cable
¼” O.D. tube connection for jet cleaning
Dissolved oxygen sensor model 10
The model 10 sensor is our standard dissolved oxygen sensor. This model features all of the above with a 1-1/2″ NPT PVC male mounting thread and provision for automatic jet clean cleaning.
Model 10PI dissolved oxygen sensor
The Model 10PI sensor is designed for on-line dissolved oxygen monitoring in large-diameter pipe. The holder is a 2″ NPT male thread in 316 stainless steel, which works with a customer-supplied 2″ Thread-O-Let. The sensor’s own integral jet includes an in-line check valve. There is a flow indication groove on the back of the sensor bracket, which must be parallel to the flow. Maximum in-line pressure is 20 psi.
Model 10HT dissolved oxygen sensor (Hot tap)
The Model 10HT sensor combines the ease of use of a hot tap with the reliability of a DO sensor. The mounting is a 2″ NPT male thread in 316 stainless steel that works with a customer-supplied 2″ Thread-O-Let, a saddle or existing piping. Integrated jet cleaning includes an in-line check valve.
OD sensor model 12 with barrier junction box model SJB-1 for class 1, div. 2
The Model 12 dissolved oxygen sensor brings all the reliability our customers expect from the Model 10 dissolved oxygen sensor to Class 1, Division 2 hazardous areas. Compatible with our single-, dual- and multi-parameter wired analyzers (SCA, DCA and MPA-48). Complies with UL STD 61010-1 & ISA STD 12.12.01 Certified to CSA STD C22.2 Nos. 61010-1 & 213
ORP measurement technology
The Model 50 holder and Model 52 replaceable ORP electrode cartridge make up the ORP sensor, featuring integrated electronics, custom geometry and a field-proven cartridge.
The electronics built into the Model 50 holder include an integrated, electrically isolated preamplifier, and enable reliable digital communications up to 2000 feet from the analyzer.
The custom geometry of our stand includes a quick-disconnect design that allows for easy cartridge replacement, reduced downtime and easy cleaning with an integrated jet.
Specifications
Measurement range: +/- 2000mV
Temperature range: 10°C to 60°C
Mounting thread 1-½” MNPT
10 m (33ft) sensor cable
¼” O.D. tube connection for jet cleaning
Supply pressures for jet cleaning
Water 35 to 50 psig
Air 40 to 60 psig
PH model 50 sensor holder
The Model 50 holder includes all the electronics needed to communicate with our continuous analyzers and interface with the cartridge. Internal electronics include a high-quality isolated preamplifier with integrated A/D conversion to maximize noise immunity and extend cartridge life. The Model 50 bracket uses our standard bracket, with a 1½” NPT PVC male thread. The bracket comes standard with tool-free 1/4″ O.D. tube connectors for cleaning the integrated jet, and 10 m of sensor communication cable. Additional cable lengths are available on request.
ORP electrode model 52
The M-52 is a cartridge-type electrode, making replacement simple and easy. The cartridge is sealed in the holder with a reliable double O-ring seal. All replacement electrodes are supplied complete with O-rings. The threaded TNC connector at the top of the electrode body ensures a reliable electrical connection with the holder.
At the center of the measuring surface is the pH-sensitive flat glass. This surface is enveloped by the flat, porous reference junction. The large surface area of this porous junction features thousands of pores for excellent contact with the sample. The electrode is surrounded by the electrode body. The electrode body contains a sealed, gel-filled, double-junction reference half-cell. This design adds an extra barrier against contaminants. It also enables the electrode to be used in applications where sulfides, heavy metal ions and similar materials are present.
PH measurement technology
The Model 50 holder and Model 51 replaceable pH electrode cartridge comprise the pH sensor, featuring integrated electronics, custom geometry and a field-proven cartridge.
The electronics built into the Model 50 holder include an integrated, electrically isolated preamplifier, which enables reliable digital communications up to 2000 feet from the analyzer, and a temperature compensation circuit.
The custom geometry of our support incorporates a quick-disconnect design that facilitates cartridge changeover, reduces downtime and facilitates integrated jet cleaning.
Our flat glass / double reference junction construction results in a field-proven cartridge that produces reliable, long-lasting measurements.
Specifications
Measurement range: 2 to 12 pH
Temperature range 10°C to 60°C
Mounting thread 1-½” MNPT
10 m (33ft) sensor cable
¼” O.D. tube connection for jet cleaning
Supply pressures for jet cleaning
Water 35 to 50 psig
Air 40 to 60 psig
PH model 50 sensor holder
The Model 50 holder includes all the electronics needed to communicate with our continuous analyzers and interface with the cartridge. Internal electronics include a high-quality isolated preamplifier with integrated A/D conversion to maximize noise immunity and extend cartridge life. The Model 50 bracket uses our standard bracket, with a 1½” NPT PVC male thread. The bracket comes standard with tool-free 1/4″ O.D. tube connectors for cleaning the integrated jet, and 10 m of sensor communication cable. Additional cable lengths are available on request.
PH electrode model 51
The M-51 is a cartridge-type electrode, making replacement simple and easy. The cartridge is sealed in the holder with a reliable double O-ring seal. All replacement electrodes are supplied complete with O-rings. The threaded TNC connector at the top of the electrode body ensures a reliable electrical connection with the holder.
At the center of the measuring surface is the pH-sensitive flat glass. This surface is enveloped by the flat, porous reference junction. The large surface area of this porous junction features thousands of pores for excellent contact with the sample. The electrode is surrounded by the electrode body. The electrode body contains a sealed, gel-filled, double-junction reference half-cell. This design adds an extra barrier against contaminants. It also enables the electrode to be used in applications where sulfides, heavy metal ions and similar materials are present.
Total Suspended Solids (TSS) measurement technology
Model 15 suspended solids sensor incorporates near infrared (NIR) technology, solid-state electronics and customized geometry. Near infrared technology offers enhanced reading reliability when solids color changes occur. Solid-state electronics increase reading consistency and digital communication reliability up to 2000 feet.
SS sensors come standard with ¼” O. D. tube connectors for integrated jet cleaning and 10 m of sensor communication cable. Additional cable length is available on request.
Specifications
Measuring range: 0 to 30,000 mg/l total suspended solids, and 0- 3000 mg/L
Accuracy: +/- 5% of reading or +/- 100 mg/l, whichever is greater.
Repeatability: +/- 1% of reading or +/- 20 mg/l, whichever is greater.
Response time: 95% in less than 60 seconds
Resolution :
1 mg/l below 1000 mg/l,
10 mg/l from 1001 to 9999 mg/l,
100 mg/l above 10,000 mg/l
Drift: less than 1% per year
Temperature range: 0°C to 60°C
Mounting thread 1-½” MNPT
10 m (33ft) sensor cable
¼” O.D. tube connection for jet cleaning
Clean jet supply pressures
Water 35 to 50 psig
Air 40 to 60 psig
TSS sensor Model 15
The Model 15 MES sensor is our standard sensor. This model features all of the above with a 1-½” NPT PVC male mounting thread.
Recommended for: 250 – 30,000 mg/l
Model 15L TSS sensor
The Model 15L sensor is designed to measure the very low concentrations of solids typically found in secondary clarifiers and plant effluents. This model features a 1-½” NPT PVC male mounting thread.
Recommended for: 0 – 1500 mg/l
TSS sensor Model 15PI
The Model 15PI sensor is designed for in-line monitoring in large-diameter pipes. Mounting is a 2″ NPT male thread in 316 stainless steel which works with a customer-supplied 2″ Thread-O-Let. The sensor’s own integrated jet includes an in-line check valve.
Recommended for: 250 – 30,000 mg/l
Model 17A TSS sensor
The Model 17A suspended solids sensor combines the ease of use of a hot tap with the reliability of the InsiteIG SS sensor. The mounting is a 2″ NPT male thread in 316 stainless steel that works with a customer-supplied 2″ Thread-O-Let, a saddle or existing piping. Integrated jet cleaning includes an in-line check valve. Maximum in-line pressure is 40 psi.
Recommended for: 250 – 30,000 mg/
Model 14 TSS sensor with Model SJB-1 barrier junction box for Class 1, Div. 2.
The Model 14 suspended solids sensor brings all the reliability customers have come to expect from the Model 15 SS sensor to Class 1, Division 2 hazardous locations. Compatible with our single-, dual- and multi-parameter wired analyzers (SCA, DCA and MPA-48).complies with UL STD 61010-1 & ISA STD 12.12.01 Certified to CSA STD C22.2 Nos. 61010-1 & 213
Wireless dissolved oxygen sensor M-20
The Model 20 (M-20) dissolved oxygen sensor is a unique product that combines advanced electronics with solid-state optical sensing technology. The sensor is based on the proven design of the Model 10 sensor family, with over 8,000 units delivered. To this proven design, the Model 20 adds the ability to mount sensors throughout the plant without having to install conduit between the sensor and the analyzer. This results in significant savings in installation costs, while offering maximum flexibility in sensor placement. No other dissolved oxygen sensor can compare with the features and benefits of this revolutionary design.
The M-20 sensor is connected to a Sensor Transmitter (ST 2) junction box. The ST 2 then communicates with the Process Transmitter (PT 2) via a ZigBee-compliant RF module. An integrated antenna provides an external line of sight of up to one kilometer.
Suspended Solids wireless sensor M-25
The M-25 sensor is our standard suspended solids sensor configuration. It includes a 1-1/2″ NPT male mounting thread, a 1/4″ quick-connect tube fitting for integrated jet cleaning, and 10 m of sensor communication cable. Additional cable lengths are available on request.
Wireless PH sensor M-28 and 51
The Model 28 (M-28) uses the Model 51 (M-51) pH electrode. The Model 28 bracket allows the user to mount pH sensors throughout the plant without having to run conduit between the sensors and the analyzer. This results in significant savings on installation costs, while offering maximum flexibility for sensor placement. The electrode preamplifier, signal conditioner and temperature compensation circuits are all integrated into the holder, making electrode replacement easy and inexpensive. No other pH system can compare with the features and benefits of this design
Please contact us at controls@cancoppas.com or call us at the appropriate office should you require additional assistance.
Contact Us