As the liquid level rises and falls, the inclination of the float is changed causing a permanent magnet in the float to be deflected which in turn repels a rotatable opposing magnet. This forced snap-action contact effect activates a micro switch.
The great variety of both the top and side mounted versions makes it easy to install the switch in any tank at any location. For the simplest level switching you can select models with fixed hysteresis, while for level control application we offer Nivelco Nivomag switches with adjustable hysteresis. Models with rubber or silicon sleeves can be applied for contaminated liquids. You can fit the Nivomag switch with an MMK type tester, to check the switching function even when the liquid levels aren’t changing